Choosing a reverse osmosis water filter in NZ
- Choose reverse osmosis when a bore water test shows something a sediment or carbon filter will not shift: nitrate, fluoride, sodium, sulphate, heavy metals or total dissolved solids.
- Reverse osmosis is the only way to deal with silica, the usual cause of white etching on shower glass in NZ. It is rough on the membranes, and silica is difficult, so ring us first.
- It is a drinking water system for one dedicated tap, not a whole house system.
- Buy the remineralising cartridge with it, and keep the pre filters changed so the membrane lasts.
- If the problem is only chlorine taste, you do not need it. A carbon filter does that for far less.
How to choose a reverse osmosis filter
Reverse osmosis is the finest filtration you can put on a domestic supply, and it has trade offs. Work through these four checks before you buy.
Check you need it
Nitrate in bore water is a real concern for infants and is common on the Hauraki Plains. Fluoride in town supply and salty coastal bore water are the other usual reasons. On bore water, get a water test first, and send it to us before you buy. We will say honestly if something simpler will do. White etching on shower glass is not always hardness. In NZ it is commonly silica, and reverse osmosis is the only way to remove it, so rule that out first. Be aware it is rough on the membranes, and silica is difficult.
Pick the system for the tap
The RO270 is the standard under sink system, rated at 270 litres a day with a faucet, for a household wanting drinking and cooking water. The ROS2700 is a continuous flow system supplied without a faucet, for higher demand or more than one outlet.
Add the remineralising cartridge
Reverse osmosis takes the calcium and magnesium out with everything else. The water comes out very pure, slightly acidic and flat tasting. A remineralising cartridge on the outlet puts the minerals back and lifts the pH towards neutral. We fit one on every system we install.
Plan the drain and the servicing
The system needs a drain connection where it is installed, and it sends some water to drain. The membrane is the expensive part, and sediment and chlorine destroy it, so the pre filters are changed on schedule. Membranes typically last 2 to 3 years on good pre filtration.
Nitrate, fluoride or salty water
RO270 with a remineralising cartridge
An under sink system with its own tap. Pair it with the IL146 or IL146Q cartridge on the outlet.
Higher demand or more than one outlet
ROS2700
Continuous flow, no faucet supplied. Ring us to plan the install.
What is your water telling you?
White etching on shower glass looks like hardness, but in NZ it is commonly silica. A softener will not remove silica. Reverse osmosis will, although it is rough on the membranes.

Every reverse osmosis product we sell, compared
Straight from the live product pages, with the live price on each one. Each listing has a model dropdown. Not sure which part fits your system? Ring us with the model number.
| Model | Use it for |
|---|---|
| Puretec Reverse Osmosis Drinking Water System | |
| RO270 | 270 litres a day, under sink, with faucet |
| ROS2700 | Continuous flow, no faucet |
| Membranes and replacement parts | |
| RET1812-75 | Membrane, 75 GPD, suits the RO270 |
| ROS-RET | Membrane, suits the ROS2700 |
| ROS-PRFKIT | Prefilter kit, suits the ROS2700 |
| ROS-CB01 | Carbon prefilter, suits the ROS2700 |
| RO-DI | Deionising polishing filter kit |
| Inline remineralising cartridge | |
| IL146 | Standard, 1/4 inch BSP |
| IL146Q | Quick change T connection |
| CO-R200 Mg+ | Magnesium weighted alternative |
Common mistakes
Fitting it to the whole house
Reverse osmosis is slow and sends water to drain. It belongs on a drinking tap, not the whole house.
Leaving out the remineralising cartridge
Without it the water is flat and slightly acidic, which is mildly hard on the copper and brass on that line.
Skipping the pre filters
Sediment blocks the membrane and chlorine destroys it. Change the pre filters on schedule, roughly every 6 to 12 months.
Buying it for the wrong problem
Reverse osmosis for a chlorine taste is overkill. Work out what the problem is first, and on bore water test it.
Ordering the wrong connection
The IL146 is a standard 1/4 inch BSP cartridge. The IL146Q has a quick change T connector. Ring us if you are not sure which you have.
Forgetting the drain
The system needs a drain connection at the install location. Check the sink cupboard before you order.
Guides and links
- Best water filter in NZHow to choose a system for your water
- Do I need reverse osmosis?What it fixes that other filters do not
- Water testing guideKnow what is in the water first
- How to change your filtersCartridges and UV lamps
- Under sink filtrationSingle, twin and UV systems
- Whole house filtrationTreat every tap
- Whole house UVFor bacteria on tank and bore water
- Replacement cartridgesKeep the pre filters fresh
Not sure if you need reverse osmosis?
Send us your water test. We will tell you honestly whether you need reverse osmosis or whether something simpler will do.