Do I Need a Pressure Tank for My Water Pump?
Call 07 863 8064Mon to Fri 8 to 5. A real person picks up.
- Whether you need a pressure tank depends on what controls your pump.
- A fixed speed pump on a pressure switch needs one, and we recommend at least an 18 litre Davey Supercell.
- A pump on an electronic controller will run without one, but a tank still cuts cycling on small draws.
- Variable speed pumps with a vessel built in need nothing added.
- Size it on draw off, not litres. Davey's datasheet gives 7.2 litres for an 18 litre tank and 22.8 litres for a 60 litre on a 200 to 400 kPa switch.
A pressure tank is a steel vessel with a rubber diaphragm inside, an air cushion on one side and your water on the other. It decides how often your pump starts. Whether you need one depends on how your pump is controlled, and the size you need depends on your pressure switch, not on the litres printed on the tank.
The short answer
- Switch. Fixed speed pump on a pressure switch: yes. We recommend at least an 18 litre Davey Supercell.
- Controller. Torrium2, PM Start or PM PLUS: optional, but a tank still cuts cycling on small draws.
- Variable speed. DynaDrive, EvoDrive, E.SYBOX: no. A small vessel is built in.
What does a pressure tank do?
Water does not compress. With only a pump and a switch, every small draw becomes its own pump start. A pressure tank fixes that by storing water under an air charge. Inside, a butyl rubber diaphragm separates the water from a cushion of air. When the pump runs it pushes water in and squeezes the air. When you open a tap, the stored water comes back out first, and the pump stays off until the pressure falls to the cut in setting.
That does three jobs. The pump starts less often, so there is less wear on the motor, the switch and the seal. The air cushion takes the shock out of the pipework, so there is less water hammer and vibration. And because the pump is not running up for every small draw, it uses less power.
Do I need a pressure tank?
It depends on what controls your pump. Find yours below.
| Your setup | Tank? | Why |
|---|---|---|
| Fixed speed pump on a pressure switch | Yes | A switch reads pressure and nothing else, so it needs a tank behind it. We recommend at least an 18 litre Davey Supercell. |
| Pump on a pressure controller (Davey Torrium2, Grundfos PM Start or PM PLUS) | Worth it | The controller runs without a tank and cuts out most of the rapid cycling. It does not remove it entirely, because a dripping tap or a small leak will still cycle the pump. A tank still cuts cycling on small draws and takes load off the pump. |
| Davey DynaDrive, Davey EvoDrive, DAB E.SYBOX | No | Each has a small pressure vessel built in and needs nothing added. Our Supercell page says to leave a tank off a variable speed pump. |
| Grundfos SQE with a CU 302 control unit | Yes, 18 litres or larger | The CU 302 needs an 18 litre or larger tank to work correctly. |
| Grundfos SBA | Ring us | We will check your model before we tell you either way. |
| Sump and dewatering pumps | No | Dewatering pumps do not need a pressure tank. |
Not sure what controls your pump? A small box with a spring, a cover screw and a tyre valve tank beside it is a switch. A slim electronic unit with indicator lights is a controller. Our guides on the pressure switch and the pressure controller show both side by side, and the variable speed pump guide covers the third type.
What size pressure tank do I need?
A tank does not give you its litres back. It gives you the draw off.
Draw off is the water the tank hands over between the pump stopping and the pump starting again. It is a fraction of the tank, and it changes with your pressure switch range, the cut in and cut out pressures. This is Davey's nominal draw off for each Supercell we sell, in litres.
| Tank | 150 to 300 kPa | 200 to 400 kPa | 250 to 500 kPa |
|---|---|---|---|
| 8 litre | 3.0 | 3.2 | 3.3 |
| 18 litre | 6.7 | 7.2 | 7.4 |
| 60 litre | 21.2 | 22.8 | 23.9 |
| 100 litre | 37.5 | 40.0 | 41.7 |
Source: Davey Supercell P tank datasheet DWP0276-4. Your switch range is in your pump manual. If you cannot find it, ring us.
So on a pump that runs 200 to 400 kPa, an 18 litre tank gives you 7.2 litres before the pump has to start, and a 60 litre gives you 22.8. A bigger tank means more water drawn off before the pump starts and fewer starts over the life of the system. It does not change your flow or your pressure.
The wrong way
Buy on the litres printed on the tank, then wonder why the pump still starts every time someone fills a kettle.
The right way
Check your switch range, read the draw off for that range, and pick the tank that covers the small draws in your house.
The 18 litre is the default we fit and recommend on any pressure system running off a switch. The 60 and 100 litre tanks are for where you want to genuinely cut cycling on a busy household. Bigger is better, as long as you have the room.
Pipe mounted or free standing?
The two small tanks mount on the pump. The two large ones stand beside it. Pipe mounted tanks fit on the pump headworks, or on top of a Davey pressure controller. Free standing tanks sit next to the pump on the foot supplied, with a 90 degree stainless elbow on the inlet so you can run the pipe in horizontally. For a free standing tank we recommend a flexible reinforced hose, so vibration and movement do not load up the fitting.
| Tank | Mounting | Diameter by height | Inlet |
|---|---|---|---|
| 8 litre | Pipe mounted | 203 by 317 mm | 1 inch male |
| 18 litre | Pipe mounted | 279 by 368 mm | 1 inch male |
| 60 litre | Free standing | 388 by 626 mm | 1 inch female |
| 100 litre | Free standing | 430 by 804 mm | 1 inch female |
Source: Davey datasheet DWP0276-4. The standard Supercell is rated to 1,000 kPa working pressure.
One rule that applies to the whole install: do not run pressure above 500 kPa (72 psi) into the house without a pressure limiting valve. 300 to 400 kPa is great pressure for most households.
How do I know if my tank has gone wrong?
Starts and stops every few seconds
This is almost always the tank, not the pump or the switch. A tank that has lost its air charge or filled with water has no draw off left, so the pump starts and stops on the smallest draw. Every one of those starts is a hit on the switch contacts, the motor and the seal.
If your pump is clicking on and off every few seconds, switch it off and check the tank before you replace anything.
Water from the air valve
Press the air valve, the same type as on a car tyre. Air should hiss out. If water comes out, the diaphragm has split and the tank needs replacing. Domestic tanks are sealed units, so it is a replacement, not a repair.
Air charge too low
The air charge drops slowly over the years. Check it with the system depressurised and the tank drained of water. It should sit just below the pressure your pump starts at. Davey's factory charge is 190 kPa on the 8, 18 and 60 litre tanks and 140 kPa on the 100 litre, so reset it to suit your own cut in setting.
If the pump cycles with every tap closed, the tank may not be the cause. A leak out on the property, or a failed non return valve, will do the same thing. Our guide on why your pump turns on and off walks through the checks in order.
Looking for the pump to go with the tank? See our house pumps, the Davey range and the Grundfos range.
Talk to us
Tell us what pump you have and what switch or controller runs it, and we will tell you if you need a tank and which one. We service this gear around Waihi and Thames every week. A real person picks up.