Pressure Tanks

A pressure tank for a water pump stores water under an air cushion so the pump starts less often. This is our range of pressure tanks in NZ: the Davey Supercell in four sizes. Whether you need one depends on how your pump is controlled, so read our do I need a pressure tank guide first. Not sure? Ring us on 07 863 8064.

Filter and sort

2 products

Pressure tank guide

Choosing a pressure tank for your water pump in NZ

The short answer
  • A pump on a pressure switch needs a pressure tank, and we recommend at least an 18 litre Davey Supercell.
  • A pump on a pressure controller does not need one but still runs better with one.
  • Variable speed pumps such as the DynaDrive, EvoDrive and E.SYBOX have a small vessel built in, so they need nothing added.
  • A tank is sometimes called a pressure vessel, and it is the same thing.
  • Size it by the draw off for your pressure switch range, not by the litres printed on the tank.

Our do I need a pressure tank guide goes through every setup in full.

Do you need a pressure tank?

It depends on what controls the pump. This is the short version from our full guide, so check there if yours is not listed.

Your setupTank?
Fixed speed pump on a pressure switchYes. A switch reads pressure and nothing else, so it needs a tank behind it
Pump on a Davey Torrium2, Grundfos PM Start or PM PLUS controllerWorth it. The controller works without one, but a tank still cuts cycling on small draws
Davey DynaDrive, EvoDrive or DAB E.SYBOXNo. A small vessel is built in
Grundfos SQE with a CU 302 control unitYes, 18 litres or larger. The CU 302 needs it to work correctly
Sump and dewatering pumpsNo

Fixed speed pump and a switch

Fit a tank

The pump starts less often, so there is less wear on the motor, the switch and the seal, and less water hammer in the pipes.

Variable speed pump

Leave the tank off

Davey says a Supercell is not recommended on variable speed pumps, which already hold the pressure themselves. See our house pumps.

How to choose a pressure tank

Once you know you need one, work through these four checks.

  1. Find your pressure switch range

    It is the cut in and cut out pressure, for example 200 to 400 kPa, and it is in your pump manual. If you cannot find it, ring us. Not sure whether you have a switch or a controller? Our pressure switch guide and pressure controller guide show both.

  2. Read the draw off for that range

    Draw off is the water the tank hands over between the pump stopping and the pump starting again. It is a fraction of the tank, and it changes with your switch range. The table below is Davey's nominal draw off for each Supercell we sell, in litres.

  3. Pick the size

    A bigger tank means more water drawn off before the pump starts and fewer starts over the life of the system. It does not change your flow or your pressure. Our default for a switch system is the 18 litre. The 60 and 100 litre are for cutting cycling in a busy household, if you have the room.

  4. Pipe mounted or free standing

    The 8 and 18 litre mount on the pump headworks, or on top of a Davey pressure controller. The 60 and 100 litre stand beside the pump on the foot supplied, with a 90 degree stainless elbow on the inlet. For a free standing tank we recommend a flexible reinforced hose.

Tank150 to 300 kPa200 to 400 kPa250 to 500 kPa
8 litre3.0 litres3.2 litres3.3 litres
18 litre6.7 litres7.2 litres7.4 litres
60 litre21.2 litres22.8 litres23.9 litres
100 litre37.5 litres40.0 litres41.7 litres

Source: Davey Supercell P tank datasheet DWP0276-4, nominal draw off by pressure switch range. So on a pump that runs 200 to 400 kPa, an 18 litre tank gives you 7.2 litres before the pump has to start, and a 60 litre gives you 22.8.

Air precharge

Inside the tank a butyl diaphragm separates the water from a cushion of air. That air is set at the factory, and Davey's precharge is 190 kPa on the 8, 18 and 60 litre tanks and 140 kPa on the 100 litre. Reset it to suit your own cut in setting. Check it with the system depressurised and the tank drained of water. The air charge drops slowly over the years, and a tank that has lost its charge has no draw off left, so the pump starts and stops on the smallest draw. Our pressure tank guide covers how to tell if a tank has gone wrong.

What we sell

Straight from the live product page and the Davey datasheet. All four sizes are on the one listing, and Davey guarantees the Supercell for 5 years. The standard Supercell is rated to 1,000 kPa working pressure.

ModelMountingDiameter by heightInlet
Davey Supercell 8 litre (24008P)Pipe mounted203 by 317 mm1 inch male
Davey Supercell 18 litre (24018P)Pipe mounted279 by 368 mm1 inch male
Davey Supercell 60 litre (24060P)Free standing388 by 626 mm1 inch female
Davey Supercell 100 litre (24100P)Free standing430 by 804 mm1 inch female

Looking for a different tank? Ring us on 07 863 8064.

Common mistakes

Buying on the litres printed on the tank

The draw off is what counts, and it depends on your switch range. Read the table first.

Adding a tank to a variable speed pump

The DynaDrive, EvoDrive and E.SYBOX already have a small vessel built in.

A tank under 18 litres with a CU 302

The CU 302 control unit needs a tank of 18 litres or larger to work correctly.

Blaming the pump when it cycles every few seconds

This is almost always a tank that has lost its air charge or filled with water. Check the tank before you replace anything.

Piping rigidly to a free standing tank

We recommend a flexible reinforced hose, so vibration and movement do not load up the fitting.

Running too much pressure into the house

Do not run pressure above 500 kPa (72 psi) into the house without a pressure limiting valve. 300 to 400 kPa is great pressure for most households.

Not sure which pressure tank?

Tell us what pump you have and what switch or controller runs it, and we will say whether you need a tank and which size.

contact@pumpstuff.co.nz  |  Waihi, 65 Kenny Street, Mon to Fri 8 to 5  |  Kopu, 74 Kopu Road, Mon to Fri 8 to 3
07 863 8064